Issues of Safe and Efficient Graphite Electrode Use

Home » Issues of Safe and Efficient Graphite Electrode Use

Graphite Electrodes Main Functions

Graphite electrodes are primarily used in electric arc furnaces (EAF) for steelmaking. They achieve steel smelting by melting the furnace charge through a high-temperature arc generated between the electrodes and the furnace charge inside the electric arc furnace. At the same time, graphite electrodes are important materials used in electrochemical reactions and are widely applied in lithium-ion batteries, fuel cells, and other fields. Their high conductivity and high-temperature resistance make them crucial materials in the steelmaking industry. Therefore, the graphite electrodes use in electric arc furnace steelmaking is very critical. Operators must strictly follow the operational requirements of graphite electrode use to ensure that the graphite electrodes perform their intended functions in the electric arc furnace.

graphite electrode process
graphite electrode process
Come and Visit Our Graphite Electrode Factory Now!

Graphite Electrode Use Steps

1. Graphite Electrode Installation

  • 1. Inspection and Preparation
    Check the surface of the graphite electrode for cracks or damage. Ensure that the electrode joint threads are clean and smooth. Wet graphite electrodes should be dried before use.
  • 2. Installing the Electrode Joint
    Firmly install the electrode joint (usually a positive electrode or negative electrode connector) into the threaded hole of the electrode with the graphite electrode nipples.
  • 3. Connecting the Electrode
    Connect multiple graphite electrodes into an electrode column using joints. During connection, keep the electrodes vertical and use a torque wrench to tighten them according to the specified torque.

2. Graphite Electrode Raising and Lowering

  • Graphite Electrode Lifting
    Remove the foam protective cap from the spare graphite electrode hole and check if the threads inside the electrode hole are intact. Use the electrode lifting mechanism to raise the graphite electrode above the electric arc furnace, ensuring the electrode can move freely up and down.
  • Electrode Positioning
    Carefully screw the joint into the electrode hole of the graphite electrode. Adjust the electrode to the appropriate position according to the position and condition of the furnace charge inside the furnace to ensure a stable arc.

3. Starting the Electric Arc Furnace

  • Preheating the Electrode
    When graphite electrode use appears for the first time or is replaced with a new electrode, perform preheating operations to avoid cracks caused by thermal stress when a cold electrode comes into contact with high temperatures.
  • Starting the Electric Arc Furnace
    Turn on the electric arc furnace power. By adjusting the electrode position, form an arc and gradually increase the current, creating a high-temperature arc between the electrode and the furnace charge to begin melting the furnace charge.
graphite electrode nipple use
final graphite electrode
Any Questions about Graphite Electrode Use, Contact Us for Free!

4. Monitoring and Adjusting During Operation

  • Monitoring Graphite Electrode Consumption
    During electric arc furnace operations, the graphite electrode will gradually be consumed. Real-time monitoring of the electrode length is necessary for timely adjustment and replacement. When lifting the electrode, place a soft material under one end of the spare electrode to prevent damage to the joint from the ground. Insert the hook into the lifting ring of the lifting device and lift the electrode steadily to prevent it from loosening at end B or colliding with other fixed devices.
  • Adjusting Graphite Electrode Position
    Adjust the electrode position at any time based on changes in current and voltage during the melting process to ensure a stable arc and efficient melting. Hang the spare electrode above the electrode, align the electrode hole, and slowly lower it. Rotate the spare electrode so that the spiral hook rotates with the electrode and reduces. When the ends of the electrodes are separated by 10-20 mm, clean the exposed parts and the joint again with compressed air. When the electrode is fully lowered, do not do so too vigorously to avoid damaging the threads of the electrode hole and joint due to intense collisions.
  • Preventing Electrode Breakage
    Avoid direct contact between the electrode and the furnace charge to prevent the electrode from breaking due to intense mechanical impact or thermal stress at high temperatures. Use a torque wrench to tighten the spare electrode until the end faces of the two electrodes are in close contact (the gap between the electrode and the joint should be less than 0.05mm).

Instructions for Using Graphite Electrodes

Instructions-for-Using-Graphite-electrodes

When installing the connector, use compressed air to clean the hole, then install the connector carefully without damaging the threads.

The graphite electrode should be stored in a clean, dry place, and avoid shaking and collision. Use a crane for handling.

Instructions for Using Graphite electrodes

When connecting the electrode, leave a gap of 20-30mm, clean both ends, and then tighten them again.

graphite electrode operation

When using the wrench to connect the electrode, it should be fully tightened to the specified position. The gap between the electrodes should not exceed 0.05mm.

graphite electrode operation

To avoid electrode breakage, please install small pieces of carbon blocks at the lower part of the joint when melting.

graphite electrode operation

To avoid electrode breakage, please avoid insulation materials.

graphite electrode rainproof tarpaulin

During transportation, electrodes must be covered with rainproof tarpaulin to ensure the graphite electrode dry.

loading unloading graphite electrode

When loading and unloading with a crane, use additional steel ropes and do not hook directly onto the steel packaging straps of the electrodes.

cut steel packaging strap of graphite electrode

When using electrodes, cut the steel packaging straps with specialized tools rather than pulling them off with a crane.

storing graphite electrode

Electrodes should be stored in a clean, dry place. When stacked in an open area, they must be covered with a rainproof tarpaulin, and the stacking height should not exceed four layers.

dry electrodes

Before use, electrodes should be dried by placing them near the electric furnace at a temperature not exceeding 150 degrees centigrade for at least 24 hours.

transport graphite electrode

When transporting and stacking electrodes with a forklift, exercise caution and avoid collisions. Only one layer is allowed at a time, and balance should be maintained to prevent slipping and breaking.

Use rotating elastic hooks with soft support pads placed under the graphite electrode joints to prevent damage to the threads.

It is not allowed to clean the electrode threads with steel wool, metal brushes, or sandpaper. Only use compressed air that is free of oil and water for cleaning.

When connecting electrodes, first clean the electrode threads. Screw the joint into one end of the electrode, and screw the lifting joint into the other end. It is not recommended to directly install the joint into the electrode currently in use in the furnace.

5. Replacing the Electrode

  • Timing for Electrode Replacement
    When the graphite electrode is consumed to a certain length or is severely damaged, it needs to be replaced.
  • Safe Operation
    Ensure the electric arc furnace is turned off and cooled before performing electrode replacement operations.
  • Installing a New Electrode
    Follow the electrode installation steps to install a new graphite electrode.

Avoid Mixing Electrodes and Joints from Different Brands

The thermal expansion coefficient of the graphite electrode nipple is designed to be smaller than that of the electrode itself. This design prevents loosening of the connection even at high temperatures during graphite electrode use.

The thermal expansion coefficients of the graphite electrode body and the joint may vary depending on the manufacturer. If electrodes or joints from different brands are mixed, it is likely that the thermal expansion coefficient of the joint will be greater than that of the electrode, resulting in loosening at high temperatures.

To Know More About Graphite Electrode Use!

Precautions for Graphite Electrode Operation

I. Inspection before Graphite Electrode Use

  • Check if the appearance of the graphite electrode is intact, especially for cracks or breaks.
  • Verify that the specifications and model of the graphite electrode are correct and meet the current requirements of graphite electrode use.
  • Ensure the contact surface of the graphite electrode is free of dirt and debris, if it is dirty for the graphite electrode surface, please clean it when necessary.
  • Confirm that the storage location of the graphite electrode is appropriate, avoiding excessively humid or high-temperature environments.

II. Precautions During Graphite Electrode Use

  • Preheat the graphite electrode before formal use to gradually increase its temperature, and commence formal operations once it reaches the working temperature.
  • Ensure the contact surface of the graphite electrode is clean and dust-free to maintain good contact quality with other equipment.
  • Avoid impacts or drops during operation to prevent damage to the graphite electrode.
  • Prevent the graphite electrode from contacting the electrolysis cell wall, rebar, or other metal materials to avoid damaging the electrolysis cell and causing safety accidents.
  • Clean and maintain the graphite electrode when not in use to ensure good performance for the next use.
  • Replace the graphite electrode promptly if it is damaged or fails to prevent production impacts.

III. Storage and Maintenance

  • Keep the graphite electrode dry during storage, away from humid environments and high temperatures.
  • Avoid impacts or wear to maintain its intact appearance.
  • Regularly maintain the graphite electrode by removing dirt and corrosion from its surface to ensure stable performance.
  • Ensure the storage warehouse is well-ventilated, avoiding excessive humidity and darkness.
  • Store graphite electrodes of different specifications or performances separately for easy identification and use.

IV. Common Problems and Solutions

  • Replace the graphite electrode promptly if cracks or breaks occur.
  • Maintain and clean the electrode surface if corrosion or dirt appears.
  • Preheat the graphite electrode if it has been stored for a long time to prevent cracks and breaks.
  • Preheat the graphite electrode before formal use to ensure it reaches working temperature.
  • Store graphite electrodes away from fire sources to prevent fire accidents.

Graphite electrodes use requires attention to various factors, from pre-operation inspections and precautions during use to storage and maintenance. Proper and reasonable use and maintenance of graphite electrodes ensure optimal performance and bring higher efficiency to production.